USD-60N Defectoscope
Distinctive features:
- Convenient and easy to use, has high power and reliability
- Equipped with a convenient TFT-display and the function of changing the background of the screen, which allows you to use the device efficiently and comfortably even in direct sunlight
- Added functions of the B-scan and, optionally, the C-scan; the ability to measure the signal, etc.
- Simultaneous demonstration of signal amplitude and distance to it is possible
- There is a temporary sensitivity adjustment for 32 points with adjustable gain and position in each of them, as well as an option for additional connection of track or speed sensors
- The presence of Ethernet-connection and, as a result, the ability to build on the basis of a flaw detector automated complexes for examining composite materials that combine ultrasonic contact, impedance and non-contact types of control
Sweep Options | 2.67 - 6,000 μs in steps of 0.01 / 0.1 / 1/10/100 μs |
Delay options | 0 to 5,900 μs in steps of 0.01 / 0.1 / 1/10/100 μs |
Prism Delay | 0 - 100 μs in steps of 0.01 / 0.1 / 1/10 μs |
Input impedance | 50 ohm / 100 ohm |
The parameters of the probe pulse (radio pulse) | Amplitude 50 or 200 V, variable duration from 16 to 500 ns, step 16 ns |
Probe Pulse Damper | 0 to 15 half-cycles, delay up to 7 half-periods |
Probe Pulse Repetition Rate | 40 Hz |
Amplifier | 0.02 -2.5 MHz (- 6 dB) |
Gain control range | 100 db; pitch 0.5, 1.2 or 6 dB |
Characteristic of temporal sensitivity adjustment | Range - up to 60 dB; 12 dB / μs The curve is built on 32 reference points obtained from control reflectors or entered manually. |
Curve Amplitude - Distance | Adjustable in height, built on 32 points |
Detection | Full, radio signal (for all scans), negative or positive half-wave, B-, D-scans |
Clipping options | Compensated up to 90% of the screen height |
Characterization of control zones | Two independent, with varying width and start across the entire sweep range. Threshold levels - during detection - from 0 to 95% of the screen height; - with a radio signal - from - 95% to + 95% (1% step). Defect detection logic is independent |
Automatic defect alarm | Sound as well as light for each zone separately |
Methods for measuring time intervals | Between signals in a zone or from zero to the first signal in a zone, at the maximum of the signal or at the edge |
Amplitude Measurement Methods | from screen height - in percent; relative to the curve "Amplitude - distance", the threshold level in the zone and the reference signal in dB |
Color display options | TFT, 130x100mm, 640x480 pixels |
A-signal characteristics | 480x300 pixels in standard mode |
Memory | 500 settings with a signal; 5,000 control protocols (envelope, signal, examination results, instrument settings, time, date and protocol name) |
Interface type | RS232 / Ethernet |
Converter Connector Parameters | 2 CP50 or Lemo0 (optional) |
Battery type | Li-Ion 8 Ah |
Battery Life | 6-8 hours |
External Power Method | 220V AC Power Supply |
Operating Temperature Range | - 25 ° С to +55 ° С |
Height, width and length of the device, mm | 190x285x50 |
Weight with batteries | 3,5 kg |
Basic equipment:
- Electronic measuring unit with built-in battery
- AC adapter 220V
- A protective case equipped with a hood and a device for fixing the device on the operator's case
- Connecting cables
- Two ultrasonic transducers 04-M26, P111-0
- 60-Ethernet cables (1 m and 2 m) for connecting to a computer
- Ethernet switch
- Documentation Kit and Software CD
- Case for transporting the device
Extended equipment:
- Basic kit
- R / s impedance converter RSP-60