MIPEX-02
Designed for use in the most hazardous and toxic environments, it has high reliability, measurement accuracy, speed and long life. MIPEX-02 methane and hydrocarbon sensors can be used in almost any gas analysis device and are available in various configurations, adapted to the needs of major customer groups and application features.
Due to the use of a two-beam circuit with signal and reference channels, the presence of a high-performance microcontroller, an integrated thermal sensor and the use of special algorithms, the sensors have high fault tolerance and provide a linearized output signal in a wide temperature range.
Type and level of explosion protection:
Ex ia I Ma U / Ex ia IIC Ga U in accordance with GOST R IEC 60079-0, GOST R IEC 60079-11, TP TS 012/2011;
Ex ia I Ma / Ex ia IIC Ga conforming to IEC 60079-0, IEC 60079-11. -55 ≤ Ta ≤ +60 ° C;
IM 1 / II 1 G Ex ia I Ma / Ex ia IIC Ga in accordance with EN 60079-0, EN 60079-11. -55 ≤ Ta ≤ +60 ° C;
Class I, Division 1, Group A, B, C, D, CONFORMS TO UL Std. 913, 60079-0, 60079-11, CERT. TO CAN / CSA Std. C22.2 No. 157-92
Characteristics:
- Product Type: Gas Sensor;
- Gas: Methane (CH4);
- Measurement range: from 0 to 100% vol .;
- Temperature range, ° C: -10 ... +40;
- RX Code: 10;
- Case Type: Plastic;
- Interface: Digital;
- Pinout: 4-legged;
- Industry sector: M1 Mines;
- Type of equipment: Portable gas analyzer (PGA);