Vibration SPEED Sensors WITH Current OUTPUT Dva121.3Xx
SPECIFICATIONS
METROLOGICAL PARAMETERS
Conversion coefficient, mA * s / mm / Range of indications of SKZ of vibration speed, mm / s
1.6 / 0-10
1,259 / 0-12,7
0.8 / 0-20
0.64 / 0-25
0.63 / 0-25.4
0.533 / 0-30
0.4 / 0-40
0.32 / 0-50
0.315 / 0-50.8
0.267 / 0-60
0.2 / 0-80
0.16 / 0-100Range of working frequencies, Hz
2-1000
3-1000
5-1000
10-1000Electrical insulation resistance between the vibration transformer circuit and the shell, MΩ, not less
40 (for 0Ex ia IIC T5 ... T6 Ga X)
1 (for PO Ex ia I Ma X)
INTERFACE
Type of output
current loop 4 ... 20 mA
Supply voltage range, V
10 ... 24
Vibration transducer connection polarity
arbitrary
EXPLOSION PROTECTION
View
intrinsically safe circuit
Marking
0Ex ia IIC T5 ... T6 Ga X / PO Ex ia I Ma X
Connection
via TIK-PLC 112 controller
through the security barrier
CONSTRUCTION PARAMETERS
Execution
with 2RMG connector on the chassis (DVA121.342)
connection to the terminal block inside the housing (DVA121.352)Overall dimensions, mm
Ø26.5x75 (DVA121.342)47x95 (DVA121.352)
Weight, kg, no more
0.24
Type of mount
hairpin M6x1 (M8x1 / M10x1 / M12x1),
M10x1.25, 1/4 "NPT, 1/2" NPT, 3/4 "NPT,
1/4 "28 UNF, 3/8" -16 UNCDegree of protection
IP65
OPERATING PARAMETERS
Range of working temperatures, ºС
-40 ... + 80 (climatic version H, for 0Ex ia IIC T5 ... T6 Ga X)
-60 ... + 80 (climatic version X, for 0Ex ia IIC T5 ... T6 Ga X)
-40 ... + 80 (for PO Ex ia I Ma X)
MANUFACTURER RELIABILITY AND WARRANTY PARAMETERS
Mean time between failures, hours, at least
40,000
Warranty period, months
24
Service life, years, not less
10
Intertesting interval
2 years