(Equipment / Material)
Model Number: HydroSense 2410
Condition: New
Location or Storage Country: Russia
Service Engineering Support: Yes
Warranty: No
Price: Call for price
Description:
HydroSense 2410 is a flow analyzer for monitoring the hydrocarbon content in water. Non-contact measurement method. Minimal maintenance. Fluorescence technology is selective for hydrocarbon levels. Continuous monitoring without chemicals and time delays. Light filtering provides high analyzer selectivity. The HydroSense 2410 uses fluorescent technology to detect water pollution from hydrocarbons. A water sample enters the measuring cell by a pump or by process pressure. Passing through the cell, the sample is irradiated with ultraviolet light and returns back to the process. The source and receiver are equipped with filters to control the wavelength of the emitted ultraviolet and received fluorescent light. Oil products dissolved in water and converted into an emulsion under the influence of ultraviolet radiation fluoresce, emitting light energy with a characteristic wavelength. The light energy intensity at this wavelength characterizes the concentration of hydrocarbons in ppm. The method is based on calibrating the device with stable water with a known hydrocarbon content and correlates well with laboratory methods.
Overview:

HydroSense 2410 uses fluorescent technology to detect water pollution from hydrocarbons. A water sample enters the measuring cell by a pump or by process pressure. Passing through the cell, the sample is irradiated with ultraviolet light and returns back to the process.

The source and receiver are equipped with filters to control the wavelength of the emitted ultraviolet and received fluorescent light. Oil products dissolved in water and converted into an emulsion under the influence of ultraviolet radiation fluoresce, emitting light energy with a characteristic wavelength. The light energy intensity at this wavelength characterizes the concentration of hydrocarbons in ppm. The method is based on calibrating the device with stable water with a known hydrocarbon content and correlates well with laboratory methods.

Operating principle:

fluorescence photometry

Range:

0-10 to 0-300 ppm linear

300 ppm to 1000 ppm trend

Accuracy:

± 1 ppm

Resolution:

0.1 ppm

Working temperature:

10 ... 50 ° C

Process temperature:

0 ... 40 ° С, 0 ... 100 ° С with a cooler

Nutrition:

= 24V or ~ 220V

Alarm Relay:

4x 10 A, programmable

Exit:

4-20mA, isolated RS-485 Modbus, HART option

Cupboard:

316 SS, Type 4X, IP65, Ex Zona 2

Sample Consumption:

at least 5 l / min

Sample Pressure:

2-100 psi