Add product
Product / Equipment

pruver

(Equipment / Material)
Model Number: ДИКТ 50.00.000 СБ
Condition: New
Export Mode: EXW
Location or Storage Country: Russia
Location: Russia, Tatarstan, Naberezhnye Chelny, Tozeles ave., 37
Packaging Details: Board Box / Case
Service Engineering Support: No
Warranty: Yes
Price: Call for price
Description:
The DIKT-50 and DIKT-100 diaphragm critical flow meter are designed to measure pressure in the well and can be an integral part of the wellhead. DICT consists of a body, on one end of which there is a smooth tubing thread GOST 633-80, on the other end of the body - a metric thread with a recess under the diaphragm, in which it is fixed and clamped with a nut with handles. The other end of the body is screwed into the flare line or welded to it through a fitting. Up to 29 versions of diaphragms with various hole diameters are included in the DICT kit (the quantity can be changed upon the request of the Customer). Depending on the flow rate of the well, a diaphragm with a specific hole is selected. Additionally, the DICT is equipped with a collector, which can be installed directly on the DICT or, if necessary, through the tubing tubing - 73 at the required distance. By installing pressure and temperature measuring devices on the collector, the flow parameters are measured in the flow part of the DICT. You can place an order, ask a question by phone: + 7-905-372-58-45 or by e-mail: esobko@tehsmart.ru
Overview:

The DIKT-50 and DIKT-100 diaphragm critical flow meter are designed to measure pressure in the well and can be an integral part of the wellhead. DICT consists of a body, on one end of which there is a smooth tubing thread GOST 633-80, on the other end of the body - a metric thread with a recess under the diaphragm, in which it is fixed and clamped with a nut with handles. The other end of the body is screwed into the flare line or welded to it through a fitting.

Up to 29 versions of diaphragms with various hole diameters are included in the DICT kit (the quantity can be changed upon the request of the Customer). Depending on the flow rate of the well, a diaphragm with a specific hole is selected.

Additionally, the DICT is equipped with a collector, which can be installed directly on the DICT or, if necessary, through the tubing tubing - 73 at the required distance. By installing pressure and temperature measuring devices on the collector, the flow parameters are measured in the flow part of the DICT.

You can place an order, ask a question by phone: + 7-905-372-58-45 or by e-mail: esobko @ tehsmart.ru

Documentation:

Techsmart NPF, Open Company

Total Employees: 65
Locations: Russia, Tatarstan, Naberezhnye Chelny
Main Products/Services: Well Research Equipment
Registration: Russia
Year Established: 2012