VIBRO-Acceleration Sensors WITH Voltage OUTPUT Dva252.6Xx
Consist of a piezoelectric vibration transducer DV-1 isp.04 (05) and a remote unit USO252.6XX located in the measuring unit;
Type of output signal - voltage (two-wire),
IEPE (ICP® compatible)
SPECIFICATIONS
METROLOGICAL PARAMETERS
Acceleration dynamic range, m / s 2
no more than 1000
Conversion coefficient, mA * s 2 / m / Range of indications of the instantaneous value of vibration acceleration, m / s 2
0 ... 25
0 ... 40
0 ... 100
0 ... 160
0 ... 200
0 ... 300
0 ... 500
0 ... 1000Range of working frequencies, Hz
2-10000
3-10000
5-10000
10-10000Electrical insulation resistance between the vibration transformer circuit and the shell, MΩ, not less
40
INTERFACE
Type of output
voltage (two-wire), IEPE (ICP® compatible)
DC output voltage, V
12 ± 0.2
The maximum amplitude value of the alternating voltage measured by the channel, V
≈ 2
Power supply by explosion-proof current source, mA
4-10
EXPLOSION PROTECTION
View
intrinsically safe circuit
Marking
0Ex ia IIC T5 ... T6 Ga X
Connection
via TIK-PLC 121 controller
CONSTRUCTION PARAMETERS
Execution
DVA252.604 (DV-1 vibration converter isp.04,
remote unit USO252.6XX, measuring unit,
safety barrier TIK-BIS-12-1
(TIK-BIS-51-7, TIK-BIS-52-7))
DVA252.632 (DV-1 vibration transducer isp.05
with 2PM connector, remote unit USO252.6XX,
measuring unit, safety barrier
TIK-BIS-12-1 (TIK-BIS-51-7, TIK-BIS-52-7))
DVA252.664 (DV-1 vibration transducer isp.05
with HIROSE connector, USO252.6XX remote unit,
measuring unit, safety barrier
TIK-BIS-12-1 (TIK-BIS-51-7, TIK-BIS-52-7))Overall dimensions, mm
Ø39.25x39.5 (DV-1 vibration transducer)
98.5x27.5x59 (USO252.6XX remote unit)
277x217x84 (measuring unit)Weight, kg, no more
0.25 (DV-1 vibration transducer)
0.1 (remote unit USO252.6XX)
2.5 (measuring unit)Type of mount
screw M4x21 (M4x28) 3 pc., magnet
Degree of protection
IP65 / IP68 (DVA252.604, DVA252.664 sensor)
IP65 (DVA252.632 Sensor)
IP20 (remote unit USO252.6XX)
IP66 (measuring unit)
OPERATING PARAMETERS
Range of working temperatures, ºС
-40 ... + 80 (vibration transducer, remote unit USO252.6XX,
climatic modification H)
-60 ... + 80 (vibration transducer, remote unit USO252.6XX,
climatic modification X)
MANUFACTURER RELIABILITY AND WARRANTY PARAMETERS
Mean time between failures, hours, at least
40,000
Warranty period, months
24
Service life, years, not less
10
Intertesting interval
2 years