×
名字和姓氏
有效的电子邮件地址。 该地址将用于系统电子邮件和通知。
使用条款
Show terms

By accessing and utilizing our servers, services, websites, or any associated content/postings, you agree (individually and on behalf of a business if applicable) to our Terms of Use (below), which we may update anytime at our discretion. If you do not agree to the Terms of Use (“Terms”), then you are not authorized to use any of our materials for either posting or viewing/search purposes.

More info

1 + 16 =
解答这道简单的数学问题并输入结果。 例如。 对于1 + 3,请输入4。
这个问题被要求找出是否你是一个人或自动发送同样的消息到多个新闻组邮件列表。
Product / Equipment

CEMS Mcs200Hw Systems

(设备/材料)
型号编号: MCS200HW
状态: New
位置或存放国家: Russia
服务工程支持: Yes
保证: No
价钱: 要求价格
描述:
The MCS200HW is a multi-component analytical system for continuous monitoring of up to 10 infrared measuring components in the flue gases of industrial combustion plants. The MCS200HW operates in the hot extraction mode: all parts in contact with the medium, from the gas sampling probe to the cuvette, are heated above the dew point and are thus protected against corrosion.
概观:

The built-in lambda probe additionally measures oxygen. Additionally, the measurement of total organic carbon can be supplemented by the integrated GMS811 FIDORi. Internal zero point monitoring allows you to quickly check measured values without span gases. A web display and predefined task assistants in the software make operation very easy.

Short review

  • Measure up to 10 IR components plus O 2 and TOC
  • Hot Extraction Measurement Technology
  • Gas production with virtually no wear thanks to the ejector pump
  • Zero point monitoring with internal adjustable filters
  • Modbus ® Certified Digital Interface
  • Web server for platform independent device management
  • Use of dry test gases for HCl and NH 3

Areas of use

  • Emission control of waste incinerators and power plants, as well as co-incineration plants, such as cement plants
  • Measurement of nitrogen oxides (NO, NO 2 , N 2 O) in nitric acid plants
  • Monitoring SO 3 in coal-fired power plants

The exact device data and product specifications may vary and are independent of the respective application and customer specification.

  • MCS200HW system

    Measured values CH 4 , CO, CO 2 , Corg , HCl, H 2 O, H 2 SO 4 , NH 3 , NO, NO 2 , N 2 O, O 2 , SO 2 , SO 3
    Measured parameters CH 4 , CO, CO 2 , Corg , HCl, H 2 O, NH 3 , NO, NO 2 , N 2 O, O 2 , SO 2
    Measurement principles Interference filter correlation, gas filter correlation
    Measuring distance
    8.48 m
    Trial amount
    200 l / h ... 400 l / h
    Measuring ranges
    CH 4 0 ... 70 ppm / 0 ... 700 ppm
    CO 0 ... 60 ppm / 0 ... 8.000 ppm
    CO 2 0 ... 25 Vol .-% / 0 ... 50 Vol .-%
    C org 0 ... 15 mg / m³ / 0 ... 10.000 mg / m³
    Hcl 0 ... 9 ppm / 0 ... 1.840 ppm
    H 2 O 0 ... 40 Vol .-%
    H 2 SO 4 0 ... 50 ppm / 0 ... 200 ppm
    NH 3 0 ... 15 ppm / 0 ... 650 ppm
    NO 0 ... 110 ppm / 0 ... 1.865 ppm
    NO 2 0 ... 25 ppm / 0 ... 240 ppm
    N 2 O 0 ... 50 ppm / 0 ... 1.015 ppm
    O 2 0 ... 25 Vol .-%
    SO 2 0 ... 26 ppm / 0 ... 875 ppm
    SO 3 0 ... 50 ppm / 0 ... 200 ppm
    Certified measuring ranges
    CH 4 0 ... 50 mg / m³ / 0 ... 500 mg / m³
    CO 0 ... 75 mg / m³ / 0 ... 10.000 mg / m³
    CO 2 0 ... 25 Vol .-%
    C org 0 ... 15 mg / m³ / 0 ... 50 mg / m³ / 0 ... 150 mg / m³ / 0 ... 500 mg / m³
    Hcl 0 ... 15 mg / m³ / 0 ... 3.000 mg / m³
    H 2 O 0 ... 40 Vol .-%
    NH 3 0 ... 10 mg / m³ / 0 ... 500 mg / m³
    NO 0 ... 150 mg / m³ / 0 ... 2.500 mg / m³
    NO 2 0 ... 50 mg / m³ / 0 ... 500 mg / m³
    N 2 O 0 ... 100 mg / m³ / 0 ... 2.000 mg / m³
    O 2 0 ... 25 Vol .-%
    SO 2 0 ... 75 mg / m³ / 0 ... 2.500 mg / m³
    Setting time
    ≤ 200 s
    Accuracy
    ≤ 2%
    Relative to the final value of the measuring range
    Sensitivity drift
    ≤ 3%: in the interval between maintenance activities, relative to the final value of the measuring range
    Zero point drift
    <3%: final value of the measuring range between maintenance
    Base point drift
    <3%: final value of the measuring range between maintenance
    Detection limit
    ≤ 2%: relative to the end value of the measuring range
    Total Organic Carbon (TOC) Measurement 0.05 mg / m³
    Comparative accuracy
    ≤ 3.3%: relative to the end value of the measuring range
    O 2 measurement ≤ 0.2 Vol .-%
    Measurement error
    ≤ 2%
    The final value of the measuring range
    Working temperature
    ≤ +1.300 ° C
    Gas temperature
    Analytic input ≤ +200 ° C
    Operating pressure
    850 hPa ... 1.100 hPa
    Gas humidity
    ≤ 40 Vol .-%
    Ambient temperature
    +5 ° C ... +40 ° C
    Storage temperature
    –20 ° C ... +70 ° C
    Environmental pressure
    850 hPa ... 1.100 hPa
    Environmental humidity
    ≤ 90%
    Relative humidity; non-condensing
    Conformity

    Approval for installations requiring approval

    2000/76 / EC (17. BImSchV)

    2001/80 / EC (13. BImSchV)

    27. BImSchV

    EN 15267

    EN 14181

    electrical safety CE
    Protection class
    IP54
    Analog outputs 0/4 ... 22 mA, 500 Ω
    Quantity depending on system configuration
    Analog inputs 0/4 ... 22 mA, 100 Ω
    Quantity depends on system configuration; decoupled
    Digital outputs 48 V AC, 0.5 A, 35 W / 48 V DC, 0.5 A, 24 W
    Quantity depends on system configuration; decoupled
    Digital inputs 3.9 V, 4.5 mA, 0.55 W
    Quantity depending on system configuration
    Modbus
    Type of integration in the bus TCP
    RTU RS-485
    PROFIBUS DP
    Note Option
    Ethernet
    Function Binding to SOPAS ET software or OPC server
    Indication
    LCD display
    Status LEDs “Power”, “Maintenance” and “Fault”
    Enter Touchpad
    Control Via LCD or SOPAS ET software, multiple access levels, password protection
    Menu languages German, English
    Dimensions (W x H x D) 808 mm x 2.208 mm x 623 mm (For details, see the dimensional drawings)
    Weight
    OK. 250 kg
    Material in contact with the medium Stainless steel 1.4571, PTFE, aluminum, coated
    Source of power
    Voltage 115 V / 230 V
    Frequency 50 Hz / 60 Hz
    Power consumption Analyzer: ± 1.000 W
    Sample gas sample line, heated: ± 95 W / m
    Gas Sampling Unit: ± 450 W
    Heated probe tube: ± 450 W
    Supporting materials
    Instrumentation air (zero gas quality) ≤ 350 l / h
    6 ... 7 bar; particle size not more than 1 micron; oil content not more than 0.1 mg / m³; pressure dew point –30 ° C
    Instrumentation air (air as a working fluid for the ejector) ≤ 1.300 l / h
    6 ... 7 bar; particle size not more than 1 micron; oil content not more than 0.1 mg / m³; pressure dew point –30 ° C
    Reference gas ≤ 350 l / h
    4 bar maximum; reference gas must meet the requirements of applicable directives and standards
    Sample gas connections
    Sample gas inlet Compression fitting for 6 mm pipes
    Auxiliary gas connections
    Air as a working fluid for an ejector DN 6/8
    Reference gas Compression fitting for 6 mm pipes
    Flue gas outlet DN 8/10
    Corrective Functions Drift correction and optical control functions using an alignment cuvette
    Control functions Automatic control cycle for zero and base points
    System components

    Gas sampling unit

    Sample gas line

    Analytical System Cabinet

    Options GMS811 FIDORi

ZIC

地点: Russia Moscow
主要产品/服务: Automatic emission control system
注册: Russia Moscow
成立年: 2004