Diesel Generator EDM L60LR (S)
Service interval 250 m/h
Warranty: 24 months, but not more than 2000 m/h
Constant power | 5 0 kW |
Reserve power | 5 3 kW |
Voltage | 230 / 400 V |
Frequency | 50 Hz |
Number of phases | three-phase |
Primary diesel engine | Lister Petter SA441G2 |
Synchronous generator | Leroy-somer TAL-A44-C |
Controller | DSE4520 MKII |
Execution | in a noise-proof casing |
Dimensions (L x W x H) | 2532 x 1050 x1502 mm |
Weight | 1400 kg |
Fuel consumption at 100% load | 18.5 l/hour |
Fuel tank | 180 l |
Autonomy | min. 8 ocloc'k |
Engine | |
Constant power | 64 kW |
Reserve power | 70 kW |
Rotation frequency | 1500 rpm |
Engine capacity | 4.10 l |
Number and arrangement of cylinders | 4 cylinders, in-line, vertical |
Cylinder operating order | 1-3-4-2 |
Speed control accuracy | +/- 5% |
Generator | |
Constant power | 50 kW |
Reserve power | 53 kW |
Voltage | 230 / 400 V |
Frequency | 50 Hz |
Type of current | alternating, three-phase |
Number of poles | 4 |
Power factor COS Ф | 0.8 |
Type | synchronous, brushless, single bearing |
Excitation system | self-stimulation |
Voltage adjustment | automatic |
Protection class | IP 23 |
Insulation class | H |
Lubrication system | |
Lubrication system | combined pressure and spray |
Oil pump type | gear type, camshaft driven |
Oil filter type | full flow cartridge filter |
Oil type | SAE 15W40 / 10W30 |
Cooling system | |
Cooling type | liquid (radiator), circulation under pressure |
Coolant type | GOST 28084-89 |
Maximum coolant temperature | 103 ºС |
Water pump | centrifugal type with belt drive |
Water pump performance | 130 l/min |
Fan power | 1.4 kW |
Electrical system | |
System voltage | 24 B |
Starting device | electric starter |
Maximum charging generator current | 25 A |
Accumulator battery | 24 V / 100 A*h |
Air supply system | |
Type | naturally aspirated |
Air filter type | filter element |
Maximum air filter resistance | 6.2 kPa |
Maximum static resistance to air flow | 5.1 kPa |
Fan air flow for radiator cooling | 120 m³/min |
Air consumption to power the engine | 2.8 m³/min |
Minimum cross-sectional area of the ventilation opening for the flow of incoming air to power and cool the engine | 0.36 m² |
Minimum cross-sectional area of the vent for outgoing air flow from the radiator | 0.36 m² |
Gas exhaust system | |
Exhaust gas temperature | 550 ºС |
Exhaust gas flow | 9 m³/h |
Muffler type | industrial - 9 dB |
Maximum exhaust back pressure | 9.8 kPa |
Noise hood | |
Purpose | Effective protection from adverse environmental factors, protection from unauthorized access, high level of noise protection |
Housing material | steel 2 mm |
Noise level (7m) | 50 dB |
Coloring | powder coating |
terms of Use | outdoor use |
Control Panel | |
Control Panel | based on DSE4520 MKII controller with LCD monitor |
Main functions | - control of diesel electric unit |
- signaling of warnings and accidents | |
- supply voltage for own needs | |
- display on the LCD display the values of the main operating parameters of the electric generator: frequency, voltage, current, engine speed, oil pressure, coolant temperature, operating hours, number of starts, generated electricity, battery voltage | |
- emergency stop button; - control of main network parameters; - automatic start when the main network parameters deviate from the specified values; - automatic shutdown and transfer of power to the main network when the main network parameters are restored; - recharging batteries; - control of the coolant heater. |