By accessing and utilizing our servers, services, websites, or any associated content/postings, you agree (individually and on behalf of a business if applicable) to our Terms of Use (below), which we may update anytime at our discretion. If you do not agree to the Terms of Use (“Terms”), then you are not authorized to use any of our materials for either posting or viewing/search purposes.

More info

16 + 2 =
解答这道简单的数学问题并输入结果。 例如。 对于1 + 3,请输入4。
这个问题被要求找出是否你是一个人或自动发送同样的消息到多个新闻组邮件列表。
添加产品
Product / Equipment

Duct fan coils

(设备/材料)
状态: New
位置或存放国家: Russia
服务工程支持: Yes
保证: Yes
价钱: 要求价格
描述:
GENERAL INFORMATION Fan coil units are divided by the type of operation into two-pipe (single-circuit) and four-pipe (dual-circuit), as well as by the type of installation: console, cassette and duct. A two-pipe fan coil uses one coolant and, depending on its temperature, can operate either in heating or cooling mode. A four-pipe fan coil has two independent heat exchangers, one of which is supplied with cold coolant, and the other with hot. Such a device can operate both for heating and for cooling. APPLICATION A centralized air conditioning system using fan coils is installed in industrial, commercial or public premises, as well as in organizations with a large number of separate rooms, for example, in office premises and apartment buildings. The choice of a centralized air conditioning system in such cases provides significant savings compared to the use of a large number of autonomous air conditioners, both in terms of the total cost of the equipment and in terms of electricity costs. PURPOSE A fan coil is a device designed to cool/heat air by circulating a heat/coolant through a heat exchanger. A fan coil is the final element of the system, providing direct cooling or heating of the air in the room using a liquid supplied from a chiller or hot water supply system. The information above is not complete, for additional data, please contact our technical specialists.
概观:

2-pipe unit.
Performance indicators under the following operating parameters:
COOLING HEAT
Inlet air temperature: +27°С
Water temp.: +7/12°С
Inlet air temperature: +20°С
Water temp.: +60/50°С

3-row heat exchanger

2-pipe unit.
Performance indicators under the following operating parameters:
COOLING HEAT
Inlet air temperature: +27°С
Water temp.: +7/12°С
Inlet air temperature: +20°С
Water temp.: +60/50°С

4-row heat exchanger


2-pipe unit.
Performance indicators under the following operating parameters:
COOLING HEAT
Inlet air temperature: +27°С
Water temp.: +7/12°С
Inlet air temperature: +20°С
Water temp.: +60/50°С

4- and 6-row heat exchanger

TECHNICAL INFORMATION

  • Cooling capacity: 18.9
  • Heat output: 36.5
  • Air capacity: up to 4400 m3/h
  • Max. working water pressure: 1600 kPa (16 bar)



OOO NPP ZEVS

地点: Tver region, Kimry city, ul. 50 let VLKSM, house 11
主要产品/服务: Refrigeration and ventilation equipment
注册: 108820, Moscow, inner ter. of the city, settlement "Mosrentgen", km. Kievskoye shosse 21st, house 3, building 1, premises 2/8