Vandal-proof Climate Control Telecommunication Cabinet ST-OU-MTS with hybrid air Conditioner
(Equipment / Material)
Model Number: ST-OU-MTS
Condition: New
Location or Storage Country: Russia
Service Engineering Support: Yes
Warranty: Yes
Price: Call for price
Description:
Vandal-proof climatic telecommunication cabinet, designed to accommodate and operate communication equipment (3G/4G base station, ⎓-48V power supply, batteries, radio relay equipment, cross and optical equipment) of the 19” standard in the amount of 27U and maintain the required temperature and humidity conditions. The cabinet has space for placing 1 group of front-terminal lead-acid batteries with a capacity of up to 190 Ah or lithium-ion batteries with a capacity of up to 100 Ah. The cabinet is equipped with an input-distribution panel for 2 inputs ~230/400 V, optionally a bidirectional multi-tariff meter with the ability to integrate into the AMR system and an ATS controller can be installed. The design of the cabinet provides a degree of protection against moisture and dust of at least IP55. To ensure the maintenance of the required climatic conditions, the cabinet can be equipped with: an air conditioner, a heat exchanger, fans and a heating element. A combination of different climate control equipment is possible.
Overview:
Indicators | Quantities |
Overall dimensions W x D x H | In accordance with the table of standard designs |
Weight of cabinet without equipment | In accordance with the table of standard designs |
Thickness of outer steel sheet | 2mm |
Climate type design | UHL1, (optional O1) |
Operating temperature range | -40 ÷ +50°C |
Degree of protection | IP55 |
Number of units for equipment |
|
Thermal conductivity coefficient of insulation λ | not less than 0.037 W/(m2 K) |
Insulation flammability class | NG |
Distance from front panels to door | not less than 100mm |
Ventilated space under the roof | 50mm |
LED light ⎓48V | Yes |
Lock resistance class | 4 |
Plinth height | 200mm |
Color of the body coating | RAL7035 |
Verkhovna Rada of Ukraine | |
Number of power inputs | 2 ("NETWORK" and "DGU") |
Supply voltage | 3F ~400V (phase-by-phase ~230V±10%) 3L+N+PE |
Introductory AB | 32A characteristic “C” |
Input AB DGU | 32A characteristic “C” |
SPD of input circuits | II+III (Level C+D) Inom=20kA or I+II (Level B+C) Iimp=12.5kA |
RCD | 16A characteristic "C", leakage current 30mA |
Service socket | 1F ~230V 16A |
Voltage distribution unit on the EPU | 3АВ 1п for each phase |
Counter | optional CE303 |
Main ground busbar | Yes, 8 connections for M6 screw |
External ground bolt | Yes, M8 |
Climate system | |
Internal temperature range provided by the SCS |
|
Power of the SCV | 0.6/0.8/1.0/1.3/2.0/2.5/3.0 kW depending on the KSh configuration |
Thermosiphon power (with hybrid design of the SVC) | not worse than 110W/K |
Noise level | no more than 55 dB(A) |
Power supply for SKV fans | ⎓-48V |
Disabling the SCS on fire/open door signal | Yes |
Compressor motor resource | Not less than 70,000 hours |
Fan motor resource | Not less than 50,000 hours |
EPU | |
Power of the EPU | 6, 9, 12, 15, 18 kW |
Input voltage range of rectifier power supply | ~85÷300V, ⎓ 95÷270V - without reducing output power ~176÷300V, ⎓ 190÷270V |
Efficiency of rectifiers | > 95.5% |
Element-by-element control of the battery | Yes |
Place for battery group | 1 group with capacity up to 190 Ah |
Number of battery groups to connect | 1, 2 or 4 |
Load contactors | 3 lines (BLVD+LLVD1+LLVD2) |
Monitoring/control channels | SNMP v. 1/2/2c/3 Wi-Fi GSM/3G/4G Web interface USB port (Host) |
Alarm sensor inputs | flooding, door, fire, impact, filter, humidity, temperature |
Number of digital inputs | 6 |
Number of relay outputs | 8 |
Efficiency Manager | Yes |
Load distribution | |
3U high panels | 48 load lines AB from 2 to 125A characteristic "C" 10kA Configuration is specified when ordering |

JSC "Energomera"